Basic error codes for Ariston refrigerator


Brand Ariston

A good option would be Ariston units belonging to the middle segment. Since 1975, they have been produced by the Merloni Elettrodomestici company, which has branches in the Russian Federation. Its founder was Vittorio Merloni.

Consumers note in the units of this brand:

  1. reasonable cost;
  2. capacity;
  3. optimal sizes;
  4. no need for regular defrosting (with No Frost technology);
  5. excellent design;
  6. automatic maintenance of the required temperature;
  7. long service life;
  8. reliability;
  9. quality;
  10. additional functions.

Ariston technology has proven itself over the years of its existence. Evidence of this is the popularity of the brand among the population.

Ariston refrigerator

Deciphering error code A2

A2 is most likely not an error, but a notification from the system that the temperature in the chamber is not sufficient for storing food. Therefore, by and large, there is no need to worry ahead of time. Judging by the manual, error a2 stands for “not normal for cooling capacity.” This can happen if the system has not reached the required temperature within a certain amount of time. In simple terms, error a2 - the Ariston refrigerator does not cool properly.

Why?

There may be several reasons for this. This error is generated by a refrigerator with a No Frost system - this should definitely be taken into account during diagnostics. Briefly the reasons are:

  1. The defrost timer has failed. The timer turns the evaporator snow build-up defrost function on and off. If the evaporator is covered with a snow coat, the cold air simply will not be able to freely leave the evaporator space and go into the chambers.
  2. The heating element is faulty. The heating element is what defrosts the frost from the evaporator. That is, if it does not heat, the evaporator also becomes overgrown with a layer of frost and does not “give” the cold to the space.
  3. The damper between the chambers is clogged. The damper is a kind of thermostat in No Frost systems. If it is clogged, the cold cannot “escape” from one chamber to another.
  4. The fan does not spin. It blows cold air from the evaporator space into the refrigerator compartment. Most likely, something is preventing its rotation (ice or a layer of frost, for example). The fan itself rarely fails. However, it happens that its blades break.
  5. Control module malfunction. The module gives commands to individual elements - compressor, fan, heater, thermostat... If the command is not given, the element will not work and there will be no frost.
  6. Capillary tube clogged. The refrigerant moves through it, through which cooling occurs. The blockage prevents free movement and cooling capacity is lost.
  7. Freon leaking from the system. Without freon there will be no cold. Definitely. Leaks often occur at the joints of tubes, filters, capillary tubes, as well as in the heating loop, etc.
  8. Compressor malfunction. He is the heart of the refrigerator. Without its operation, the refrigerant will not move through the system and you should not expect cold.

These are not all the reasons why Hotpoint Ariston refrigerators display error a2. We discussed the lack of cooling in more detail in this article: why the refrigerator does not cool.

What to do?

We always recommend our readers not to poke around where only professionals poke around. Based on this, you have only 3 options:

  • You are a refrigerator pro.
  • You are not a pro from Ufa.
  • You are not a pro and not from Ufa.

If you belong to the first point, then everything is clear - you diagnose and repair it yourself. If you belong to the second point, then you are very lucky! Congratulations! We provide at-home refrigerator repair services in Ufa. If you are not from our city, don’t worry, there will be professionals in your city. Ask Yandex or Google.

Don't forget to share our materials on social networks. Useful knowledge to the people!

Every home has a refrigerator; without it, long-term storage of food is impossible. Today, those who want to purchase this household appliance have a wide choice. The quality of food and the health of family members depend on the performance of the refrigerator. Reviews from already decided consumers will help you choose the right model.

Exploitation

Hotpoint Ariston refrigerators perform functions via electronic control. Temperature control and the No Frost option, switching operating modes of the freezer is impossible without an electronic unit.

If problems occur, a code appears on the display indicating their location. This makes the troubleshooting process easier. Models whose prices are more affordable have indicators that reflect possible problems. Their appearance provokes a corresponding light signal, on the basis of which a conclusion is drawn about the need for repair work.

The indicator, like the code, identifies the area where the damage occurred, but does not specify the cause. This set of functions ensures long-term operation of the household appliance.

Hotpoint-Ariston HBD 1201

Decoding other errors

In total, there are 19 errors found in Ariston automatic machines. After a detailed look at the most common ones, let’s briefly look at the rest. These problems are signaled by the following codes:

  1. F3 indicates a breakdown of the temperature sensor. To solve the problem, check the condition of the circuit up to the controller and measure the resistance on the sensor itself. For normal operation, its value should be 20 ohms. Broken parts found during inspection are replaced.
  2. Error f6 appears only in models made on the Arcadia platform. It indicates a problem with the drum door locking system. This code also appears in Dialogic models when the control buttons are broken. If there is a problem with the drum, check the door for foreign objects and close it tightly until it clicks. Button failure occurs due to stuck or damaged contacts.
  3. Code f10 appears when there is no response from the water level sensor. The problem occurs due to improper connection to the sewer, lack of water in the water supply, or a break in the circuit going from the control board to the sensor.
  4. The f12 symbols appear on the display when communication between the display module and the control unit is lost. In this case, these parts and their connections are checked for defects.
  5. Error f13 occurs due to a broken sensor responsible for the drying temperature. Eliminate the malfunction by replacing the part or worn contacts.
  6. Codes f14, f15 indicate a breakdown of the heating element or contacts on it.
  7. Error f16 appears on SMA with vertical linen laying. She says that the sensor responsible for blocking the drum has broken down. This usually occurs due to the valves not being tightly closed. But the sensor or the contacts on it may fail.
  8. Code f17, also known as door, appears when the door is not closed tightly enough. The device is checked for interference. If there is none, then the fault is in the part that blocks the hatch during the cycle. It is replaced with a new one.

Review of the Hotpoint Ariston RMBA.1185.1F model

This is a two-chamber household appliance in which the freezer is located at the bottom. The Hotpoint Ariston RMBA.1185.1F refrigerator has one compressor, two doors, and is controlled by an electromechanical system.

The Hotpoint Ariston RMBA.1185.1F model is equipped with:

  1. No Frost option;
  2. possibility of super freezing;
  3. freshness zone.

Refrigerator Hotpoint-Ariston RMBA 1185

Errors when operating the Ariston refrigerator

Common malfunctions include:

  1. noise, knocking or rattling that occurs during operation of the unit;
  2. the appearance of too much ice;
  3. shutdown of a household appliance that occurs immediately after it is put into operation

The cause of this problem may be a relay (starting, protective), a compressor, or a failed winding. In the latter case, the machine constantly breaks down because the wires overheat. If the compressor is to blame, then the root cause is a breakdown of the sensor responsible for the temperature. It, in turn, is damaged due to insufficient interaction with the motor of the household appliance, insufficient temperature for the refrigerator compartment

This problem can be caused by a blockage formed in the capillary pipeline. It entails disturbances in the movement of the refrigerant, as well as:

  1. formation of smudges;
  2. lack of response to turning off the light;
  3. ice freezing on the walls of the refrigerator (example in the photo).

Snow freezing in the refrigerator

In this case, the reason is non-compliance with operating rules. New generation Ariston refrigerators are defrosted once every six months. If the unit is equipped with the No Frost function, then this problem is a consequence of problems with the thermostat.

If you have problems with Hotpoint Ariston refrigerators, you must contact the service center specialists. They will repair failed parts without damaging other important parts of the household appliance, which cannot be guaranteed when trying to repair the refrigerator yourself.

Ariston refrigerator error codes (A2)

Error codes for Ariston refrigerators (A2) help to promptly recognize errors or identify errors in operation. Equipment under the Ariston brand is very popular in Russia. Refrigerators of the brand are distinguished not only by their stylish design, excellent technical characteristics and a wide range of functions, but also by their own self-diagnosis system, which warns the user of possible problems in the functioning of the refrigerator.

What does error code A2 mean?

Error codes for the Hotpoint Ariston A2 refrigerator are rather a notification from the self-diagnosis system that the temperature in the refrigerator is too high for proper food storage. Therefore, you should not immediately sound the alarm. According to the refrigerator manual, this error is interpreted as non-compliance with the cooling capacity standard. This happens if the refrigerator was unable to reach the desired temperature within a certain time. To put it simply, A2 indicates that the refrigerator is not cooling well.

There are many reasons for this error in work. If a refrigerator with No Frost produces an error, this will certainly be taken into account when conducting diagnostics. The main reasons for insufficient cooling are as follows.

  1. Defrost timer. Performs the function of turning on and off defrosting the evaporator from accumulated frost. The formation of a snow coat leads to the retention of cold air - it cannot provide cooling to the chambers. A broken defrost timer is replaced with a new part.
  2. heating element. It is he who is responsible for defrosting the evaporator. This is a special heating element. During operation, it can burn out, and sometimes the contacts simply oxidize or come off. The heating element must be removed and its condition checked.
  3. Shutter between chambers. Serves as a thermostat in refrigerators with No Frost. Sometimes it becomes clogged, creating an obstacle to the passage of cold air from one chamber to another.
  4. Fan. Provides cooling of the main compartment by forcing cold air from the evaporator. Failure of the fan, its blades, or accumulation of snow and ice lead to the fact that cold air stops flowing. In this case, cooling may be completely absent.
  5. Control module. Monitors the operation of the entire refrigerator as a whole, including the diagnostic system. It processes incoming information and issues commands to components - fan, compressor unit, thermostat, heating element. If no commands are received, then the node does not work.
  6. Capillary pipeline. A very thin tube through which the refrigerant moves. Due to the small internal diameter, blockages and plugs often form in it, the movement of freon is suspended - cooling capacity is lost or cooling becomes uneven.
  7. Compressor unit. It can be called the heart of the refrigerator. If it wears out, the cooling capacity decreases and the cooling efficiency drops.

These are only some of the problems due to which the A2 symbol may appear on the refrigerator display. Also, do not exclude wear of the sealing rubber, freon leakage, or operating conditions that do not comply with the instructions. In any case, you need to immediately contact the staff of the Gnome Workshop. We know everything about refrigerators; we have a full set of original spare parts and professional tools in stock. You can call our technician at any time of the day - he will promptly arrive upon request, carry out repairs, and leave you with a full contract for services and a warranty for spare parts.

Factors causing breakdown

The main cause of breakdowns in the unit is negligence shown by the consumer during operation. If he has not read the instructions supplied with the refrigerator, he may make serious mistakes in its maintenance and use.

Most often, malfunctions occur due to:

  1. opening the unit for a long time;
  2. the door is not pressed tightly;
  3. placing finished products in the refrigerator that have not reached the required temperature;
  4. lack of regular defrosting as prescribed in the operating instructions.

Therefore, do not ignore the manufacturer’s recommendations regarding the care of your purchased household appliance. Compliance with them in full is a guarantee of uninterrupted operation of the refrigerator for the next 89 years.

Open refrigerator

What does error F02 mean?

Almost every operating manual for a washing machine from Ariston says that error F02 should be interpreted as follows:

  • failure or breakdown of the tachometer;

  • Ariston car engine failure;

  • a break in the electrical wiring, problems in the contact group;

  • failure of the module responsible for process control.

More than sixty percent of cases of error F02 confirm the failure of the electric motor or tachometer. In other situations, the problems lie in the wires and contacts, the control module of Ariston washing equipment.

Fault codes

Like other modern refrigerators, Ariston units have a clear list of fault codes, through which identifying and eliminating the problem takes a minimum of time.

Each code reflects violations that occur in a specific segment of a household appliance.

Among them are errors in (on):

  1. compressor (F01, F02);
  2. power units (F03);
  3. fan (F04, F11, F13);
  4. heating element (F06, F07);
  5. valve with solenoid drive (F08);
  6. software (F09);
  7. damper (F10, F05);
  8. electronic unit (F14);
  9. control and indication boards (F28, F12);
  10. source of consecration (F20);
  11. touch display (F40);
  12. thyristor (F15).

The list of errors for Hotpoint Ariston refrigerator models may vary depending on the available options and design features.

Troubleshooting

Hotpoint Ariston fault codes

If you see an error code on the screen, try rebooting the device. To do this, unplug it from the network for 15-20 minutes. After turning on, look at the display. If the icons appear again, look for the explanation in the instructions or in our table.

The following are errors that indicate problems with the keys on the control panel.

Failures A1 and A2 in Hotpoint Ariston refrigerators

Failure code A1 means that the temperature in the compartments is higher than normal.

What you can do yourself:

If you have recently loaded food into the chamber, wait 20-30 minutes for the temperature to return.

If these methods do not help, it is better to consult a specialist.

Error A02 indicates that the temperature in the freezer compartment is too high. The steps are the same as in the previous case. Additionally, you can check the thermostat to see if the values ​​are set correctly.

Now you know what to do if the code appears on the screen. Do not delay the check so that the breakdown does not become fatal.

Hotpoint-Ariston technology is very popular in Russia. In addition to washing machines, blenders, meat grinders, microwaves, toasters and other appliances, refrigerators from this manufacturer are often found. They are distinguished by modern design, functionality, as well as low cost and convenience. The latter also includes notifying the user about possible problems in the unit. One of the most common notifications is error A2 in Hotpoint Ariston refrigerators.

Errors A1 and A2 in the Ariston unit

A separate group includes faults displayed on the display under codes A1 and A2. They appear when the temperature regime is violated.

A dangerous increase in temperature (A1) leads to the establishment of 0 degrees Celsius so that the consumer uses the products for their intended purpose in the next 24 hours. Problems in the software, heating element or temperature sensor can cause such a reaction in the refrigeration unit. To identify and eliminate them, you should call a specialist.

If the problem that arose was not resolved within the allotted period of time, then code A2 is displayed on the display. In this situation, it is necessary to repair the unit and check the quality of the products stored in it. It is likely that they will be spoiled.

The reason for the increase in temperature in the refrigerator compartment may be:

  1. failure of the motor compressor;
  2. damage to the sensor responsible for the temperature regime;
  3. problems with the control system;
  4. problems with the heater in the evaporator;
  5. Freon leak.

As a result, the unit will waste more electricity while generating insufficient cooling temperatures.

Refrigerant leak in refrigerator

Description of possible codes

Almost any possible malfunction in Ariston units has its own individual code, which is displayed on the built-in display. As a rule, the longer the unit is in regular use, the more likely it is to detect breakdowns.

Error codes

The most common Ariston error codes:

  • F01 - problems with the operation of the motor-compressor, the relay is faulty;
  • F02 – power supply does not reach the motor;
  • F03 – there is a problem in the power components of the device, the board may break;
  • F04 – the fan in the freezer is faulty;
  • F05 – problems with the damper;
  • F06 - the electrical circuit on the heating element is damaged;
  • F07 – complete absence of electrical voltage on the heater;
  • F08 – the solenoid valve is broken and needs to be replaced;
  • F09 – software malfunction;
  • F10 – malfunction in the secondary circuit area or the damper is broken;
  • F11 – lack of power supply to the ventilated appliance in the refrigeration unit;
  • F12 – communication failure between the built-in boards responsible for control and indication;
  • F13 – the ventilation system is broken;
  • F14 – failure of the electronic department;
  • F15 – thyristor failure;
  • F17 – the solenoid valve is broken or the special vacuum pump is malfunctioning;
  • F20 - problem with lighting in the refrigerator compartment;
  • F28 - the part responsible for the indication is damaged;
  • F40 - the button on the touch screen is broken.

The above codes are described in detail in the instructions for the Ariston refrigerator. You will need the help of a specialist to eliminate the problems and restore the unit’s functionality.

Debugg

To solve the problem you need to:

  1. Read the operating instructions.
  2. Restart the household appliance.

To do this, turn off the refrigerator from the network and set both temperature regulators to the zero position. Then turn on the unit and set the required temperature.

If the reboot does not help and A1 (A2) appears on the display again, you need to check the operation of the electronic unit. This is done as follows:

  1. turn on the refrigerator (as in step 1), first removing the terminals from the solenoid valve;
  2. set the “both cameras together” mode;
  3. We watch the temperature rise.

If no changes are observed, then the triac and/or microcontroller port are most likely damaged. In the latter case, the part cannot be restored. Independent troubleshooting, even if following the instructions, entails a refusal to repair the Hotpoint Ariston refrigerator under warranty.

Error codes

Modern Hotpoint Ariston refrigerators are equipped with a self-diagnosis system. In the event of a breakdown, the device independently determines the malfunction and reports it with a numerical-alphabetic code on the display or by flashing indicators . However, the first appearance of the code on the screen may be caused by a system failure. It is necessary to unplug the refrigerator for 20-30 minutes, and then plug the plug into the outlet again. If the error appears on the screen again, then there is a high probability that there is a reason. To decipher the code and determine the malfunction, you must refer to the operating instructions.

Depending on the type of malfunction, several dozen error codes may appear on the display. The most common symbols are shown in the table below.

Error codingFault interpretation
F01This error code indicates that the engine start relay is not working correctly. It is necessary to inspect the part for mechanical damage and traces of burning, and then test it with a multimeter. If a breakdown is detected, the relay will need to be replaced with a new one.
F02The start relay is open and will not start. As a rule, this is due to overloads or power surges in the network. To eliminate the error, diagnostics and subsequent replacement of the part will be required.
F03The control board is not working properly. It is recommended to entrust the diagnosis and troubleshooting of this unit to professionals. DIY repairs are not possible.
F04The fan inside the freezer is broken. This problem often occurs due to ice freezing, broken wiring, power surges, and drying out of the lubricant in the engine bearings. To fix the breakdown, you need to defrost the device, and then update the wires, apply lubricant or replace the fan motor.
F05This error indicates a broken control valve. To fix the problem, you will need to install a new part.
F06The code indicates that the sensor responsible for the operation of the defrost heater is faulty. For diagnostics and subsequent replacement, it is recommended to contact specialists.
F07In this case, the wiring of the heating element responsible for defrosting is damaged. It is necessary to inspect the wires and replace any broken or burnt ones.
F08The engine solenoid valve is damaged. Diagnostics and subsequent repairs, possibly replacement, will be required.
F09EEPROM error. It indicates a failure in the control module firmware. Need diagnostics and flashing of the board.
F10For refrigerators with No Frost technology, this code means a problem with the damper. For equipment with a drip system, this is an alarm about a switching valve error. Consultation with professionals and subsequent repair of the unit are required.
F11The fan is faulty due to a control failure. A part needs to be replaced.
F12The code indicates that the wires going from the board to the screen or their connections are broken. It is necessary to inspect the contact points and wiring, and then carry out repairs (if a problem is detected).
F13Fan failure. The part should be replaced.
F14In this case, the control board is faulty. Diagnosis and installation of a new unit is required.
F15The thyristor that controls the heater is broken. The unit needs to be replaced.
F16This code indicates two errors: the fan blades in the refrigerator compartment do not work or the element that controls the operation of the heating element is broken. In both cases, diagnostics and subsequent repairs are necessary.
F17There are also two possible problems: a broken pump or an electronic valve. We need diagnostics and then replacement or repair of the faulty unit.
F20The light in the refrigerator does not come on. The light bulb needs to be replaced.
F21NTC sensor malfunction. The broken element needs to be replaced.
F22, F23Broken NTC in the refrigerator or evaporator. In this case, you will need to call a specialist.
F24, F25The NTC in the freezer or evaporator is faulty. Do-it-yourself repair is impossible; professional help is needed.
F26Broken NTC in a refrigerator with a drip system. You will need help from service center representatives.
F28The board responsible for the display is damaged. It is necessary to contact specialists for repairs.

In addition to the above codes, you can see errors on the refrigerator screen indicating that a control key is broken:

  • F40 – “Start”;
  • F41 – “I Care”;
  • F42 – “Vacation”;
  • F43 – “I Party”;
  • F44 – “Ever Fresh”;
  • F45 – “Super Freeze”;
  • F46 – “Super Cool”;
  • F47 – “Emergency notification”;
  • F49 – “Frigo+”;
  • F50 – “Frigo-”;
  • F51 – “CCZ”;
  • F52 – “Freezer+”;
  • F53 – “Freezer-”.

To eliminate one of the above errors, you need to check the wires from the button to the control unit, as well as inspect and test the contacts. If necessary, you will need to order and install a new button to replace the broken one.

On a note! In addition to the codes described above, errors A1 or A2 may appear on the display of a two-chamber Ariston refrigerator. The first reports that the temperature in the device is higher than necessary. The second is displayed if the temperature in the freezer has exceeded the permissible limit.

Rating
( 1 rating, average 4 out of 5 )
Did you like the article? Share with friends:
For any suggestions regarding the site: [email protected]
Для любых предложений по сайту: [email protected]